Consider the Little Giant APCP-1700 577301 when automatic cover-water removal fits your setup, the real cord route reaches a suitable outlet, and you can provide a practical discharge line. Plan the hose before buying: the current manual recommends 1-inch inside-diameter tubing for performance, but does not guarantee a flow rate for your installed hose. Resolve Little Giant’s conflicting switch and cold-weather information before relying on those details.
This is a researched purchase review, not a pump test. We reopened the manufacturer page and inspected its linked current 115V manual on November 4, 2026. No measured pumping time, durability or comparative performance is claimed.
Match the actual pump and package
| Purchase check | Verified information and what to confirm |
|---|---|
| Identity | Little Giant lists 577301 as APCP-1700; match both identifiers |
| Power | 115 V, 60 Hz, 1/3 HP; an outlet and circuit must meet the supplied instructions and local requirements |
| Cord | The product page specifies 25 feet; the manual prohibits extension cords |
| Discharge | The page lists 1-inch FNPT with a 3/4-inch garden-hose adapter; confirm the supplied fittings |
| Service part | The manufacturer lists replacement discharge adapter 177343 |
| Switching | Automatic float control; published start depths differ, as explained below |
The existing commercial link is an Amazon search, not one fixed offer: search Amazon for APCP-1700 577301 . Check the seller’s exact model, contents and return terms. A similarly named pump or adapter alone is not the same purchase.
The current sources disagree on flow
Little Giant’s product page and linked manual both publish values against head, but the values differ:
| Head | Product-page GPH | Current-manual GPH |
|---|---|---|
| 1 ft | 1,700 | 1,745 |
| 5 ft | 1,400 | 1,540 |
| 10 ft | 1,000 | 1,230 |
| 15 ft | 700 | 850 |
| 20 ft | Not tabulated | 490 |
Both give a 26-foot shutoff head. That is the no-flow endpoint, not a useful pumping rate. These differences are in manufacturer sources, not merely retailer rounding. Ask Little Giant which data apply to the unit being supplied if the distinction affects your purchase.
The current manual recommends 1-inch inside-diameter tubing and permits connection through the garden-hose adapter. Hose length, internal diameter, fittings and elevation determine the installed resistance. The older 50-foot-hose estimate previously used in this review is not a performance promise in the current linked manual. Do not assume every garden hose delivers 500 GPH or every 1-inch line delivers 1,700 GPH.
Rain-load worksheet: a planning example
Estimate collected rain with gallons = area in square feet × rain depth in inches × 0.623. For a simple rectangular footprint, one inch of rainfall gives the following approximate volumes. The two flow columns are illustrative constant-rate calculations, not measurements or hose ratings:
| Footprint | Gallons per inch | Minutes at an assumed 1,700 GPH | Minutes at an assumed 500 GPH |
|---|---|---|---|
| 16 × 32 ft | 319 | about 11 | about 38 |
| 18 × 36 ft | 404 | about 14 | about 48 |
| 20 × 40 ft | 499 | about 18 | about 60 |
Calculation: minutes = gallons ÷ GPH × 60. At the assumed 500 GPH, flow is about 29% of 1,700 GPH and time is about 3.4 times longer. This shows why a restriction matters; it does not establish that this pump can keep up with a particular storm. Continuing rain, uneven collection, cycling, debris and installed flow change the result.
The cover-pump comparison adds cord-layout examples and alternative pump specifications. For circulation-system symptoms rather than cover water, use the flow-and-pressure diagnosis .
Automatic depth does not mean a dry cover
The current manual lists a 2.5-inch start and a 1-inch stop. Little Giant’s product page lists a 2-inch start and shutoff below 1 inch. Confirm the supplied unit’s specifications; do not silently combine the page’s earlier start with the manual’s higher flow.
These are local depths at the pump, not a uniform layer across the whole cover. Positioning, cover shape and water access affect operation. A one-inch shutoff does not promise that the cover will be dry. Follow the cover and pump instructions for placement; never stand or walk on a cover to position equipment.
Wayne’s WAPC250 and Superior’s 92395 each publish a 3/4-inch shutoff. That is a specification difference, not proof from testing that either leaves less water on your particular cover.
Measure the whole cord route
Use this layout check: outlet to pool edge + wall or coping climb + edge to the pump position + necessary slack. A straight ground-level measurement can miss much of an above-ground pool’s route.
The 25-foot cord cannot be extended under this pump’s instructions. If it does not reach a suitable outlet, have a qualified electrician assess the installation before purchase. Keep connections away from rising water and follow grounding, circuit and GFCI requirements. Do not move the pump to an ineffective location just to make the cord reach, lift it by the power cord or handle powered equipment from a wet surface.
Freeze guidance needs manufacturer clarification
The current manual warns against allowing the pump to freeze. Its maintenance page also says that, if it remains installed during freezing conditions, its power cord must remain connected. Those statements need clarification for the actual unit and installation; they do not support an unconditional leave-it-out recommendation or a generic instruction to unplug an installed pump when a freeze arrives.
Before purchasing for freezing weather, obtain Little Giant’s applicable winter procedure and plan how it will be carried out safely. Do not operate a frozen pump or obstructed discharge based on this review. If you need unattended operation through freezing weeks and cannot resolve that requirement, this is not a defensible purchase yet.
For maintenance or storage, use the supplied shutdown and handling instructions. Keep equipment separate from stored chemicals; the tablet-storage guide covers that separate storage decision.
The upkeep behind automatic operation
Automatic switching does not remove inspection work. The current manual calls for daily operating checks during the rainy season. Debris can obstruct the intake or float, and a discharge route that returns water to the cover defeats removal. Follow the specified power-isolation and cleaning procedure before touching the pump or switch.
The cover must also be appropriate for the pool. The above-ground winter-cover guide explains sizing and water-supported installation; a cover pump does not make an ordinary winter cover a safety cover or guarantee that every puddle reaches the intake.
Compare alternatives by the constraint you need to solve
- Wayne WAPC250: published start 2-1/8 inches, stop 3/4 inch, 25-foot cord and retrieval rope. Its manual excludes storable pools and limits automatic pumping height to 13 feet; a larger headline flow does not override those restrictions.
- Superior Pump 92395: published start 1-1/2 inches, stop 3/4 inch, 25-foot cord and 2,100 GPH at zero head. Its instructions also prohibit freezing exposure. Compare its curve against the actual route.
- Little Giant PCP550: manual operation requires supervision. The manufacturer manual gives 500 GPH at one foot and a 2.5-inch minimum depth to maintain prime; it is not a shallow-water automatic substitute.
Use the four-pump comparison for those model-specific limits. Different published test conditions do not establish a winner for an unmeasured installation.
Purchase decision
The APCP-1700 is a candidate for automatic cover-water removal when fit, outlet, discharge and inspection requirements are satisfied. A garden hose does not automatically rule it out, but it removes any basis for assuming headline flow without a route assessment. Defer purchase if cold-weather instructions, switch depth or the supplied version’s performance remain material unresolved questions.